Photo | Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Voltage-Rated | Size/Dimension | Width | AirFlow | StaticPressure | BearingType | FanType | Features | Noise | Power(Watts) | RPM | Termination | IngressProtection | OperatingTemperature | ApprovalAgency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
07530GA-12K-AA-00BLOWER 75MM X 30MM 12VDC STD 2 W |
3611 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | 07530GA | Active | 12VDC | Square/Rounded - 75.7mm L x 75.7mm H | 30.00mm | 7.4 CFM (0.207m³/min) | 0.200 in H2O (49.8 Pa) | Ball | Blower | Auto Restart | 29.5dB | 1.44 W | 2200 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | - |
![]() |
07530GA-24J-AA-00BLOWER 75MM X 30MM 24VDC STD 2 W |
2542 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | 07530GA | Active | 24VDC | Square/Rounded - 75.7mm L x 75.7mm H | 30.00mm | 6.7 CFM (0.188m³/min) | 0.160 in H2O (39.8 Pa) | Ball | Blower | Auto Restart | 28.0dB | 1.44 W | 2000 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | - |
![]() |
109R0605F4D01FAN 60X25MM 5VDC LOCK |
3879 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 5VDC | Square - 60mm L x 60mm H | 25.00mm | 15.5 CFM (0.434m³/min) | 0.118 in H2O (29.4 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 24.0dB(A) | 1 W | 3200 RPM | 3 Wire Leads | - | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL |
![]() |
109R0605M4011FAN 60X25MM 5VDC RBLS TACH |
3768 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 5VDC | Square - 60mm L x 60mm H | 25.00mm | 12.7 CFM (0.356m³/min) | 0.079 in H2O (19.6 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 20.0dB(A) | 650 mW | 2600 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0612D401FAN 60X25MM 12VDC TACH |
3203 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 25.00mm | 25.4 CFM (0.711m³/min) | 0.295 in H2O (73.5 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 37.0dB(A) | 2.52 W | 5150 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0612D4D011FAN 60X25MM 12VDC RBLS LOCK |
2710 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 25.00mm | 25.4 CFM (0.711m³/min) | 0.295 in H2O (73.5 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 37.0dB(A) | 2.52 W | 5150 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0612M4011FAN 60X25MM 12VDC RBLS TACH |
3941 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 25.00mm | 12.7 CFM (0.356m³/min) | 0.079 in H2O (19.6 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 20.0dB(A) | 720 mW | 2600 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0624F4011FAN 60X25MM 24VDC RBLS TACH |
3576 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 24VDC | Square - 60mm L x 60mm H | 25.00mm | 15.5 CFM (0.434m³/min) | 0.118 in H2O (29.4 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 24.0dB(A) | 1.2 W | 3200 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0805F4D01FAN 80X25MM 5VDC LOCK |
2056 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 80 | Active | 5VDC | Square - 80mm L x 80mm H | 25.00mm | 32.5 CFM (0.910m³/min) | 0.114 in H2O (28.4 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 26.0dB(A) | 1.25 W | 2600 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0812F401FAN 80X25MM 12VDC TACH |
3552 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 80 | Active | 12VDC | Square - 80mm L x 80mm H | 25.00mm | 32.5 CFM (0.910m³/min) | 0.114 in H2O (28.4 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 26.0dB(A) | 1.32 W | 2600 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0812L4D01FAN 80X25MM 12VDC LOCK |
3592 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 80 | Active | 12VDC | Square - 80mm L x 80mm H | 25.00mm | 23.0 CFM (0.644m³/min) | 0.059 in H2O (14.7 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 20.0dB(A) | 720 mW | 1850 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0812L4D011FAN 80X25MM 12VDC RBLS LOCK |
3306 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 80 | Active | 12VDC | Square - 80mm L x 80mm H | 25.00mm | 23.0 CFM (0.644m³/min) | 0.059 in H2O (14.7 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 20.0dB(A) | 720 mW | 1850 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0812M4011FAN 80X25MM 12VDC RBLS TACH |
3751 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 80 | Active | 12VDC | Square - 80mm L x 80mm H | 25.00mm | 29.3 CFM (0.820m³/min) | 0.090 in H2O (22.4 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 23.0dB(A) | 1.08 W | 2350 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0812M4D01FAN 80X25MM 12VDC LOCK |
2837 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 80 | Active | 12VDC | Square - 80mm L x 80mm H | 25.00mm | 29.3 CFM (0.820m³/min) | 0.090 in H2O (22.4 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 23.0dB(A) | 1.08 W | 2350 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0824L401FAN 80X25MM 24VDC TACH |
2932 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 80 | Active | 24VDC | Square - 80mm L x 80mm H | 25.00mm | 23.0 CFM (0.644m³/min) | 0.059 in H2O (14.7 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 20.0dB(A) | 960 mW | 1850 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0824L4011FAN 80X25MM 24VDC RBLS TACH |
2149 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 80 | Active | 24VDC | Square - 80mm L x 80mm H | 25.00mm | 23.0 CFM (0.644m³/min) | 0.059 in H2O (14.7 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 20.0dB(A) | 960 mW | 1850 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
109R0824L4D01FAN 80X25MM 24VDC LOCK |
3948 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 80 | Active | 24VDC | Square - 80mm L x 80mm H | 25.00mm | 23.0 CFM (0.644m³/min) | 0.059 in H2O (14.7 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 20.0dB(A) | 960 mW | 1850 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
|
109R0605M401FAN 60X25MM 5VDC TACH |
3293 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 5VDC | Square - 60mm L x 60mm H | 25.00mm | 12.7 CFM (0.356m³/min) | 0.079 in H2O (19.6 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 20.0dB(A) | 650 mW | 2600 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
|
109R0612S4011FAN 60X25MM 12VDC RBLS TACH |
2620 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 25.00mm | 23.0 CFM (0.644m³/min) | 0.228 in H2O (56.8 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 33.0dB(A) | 2.04 W | 4600 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
|
109R0624G4011FAN 60X25MM 24VDC RBLS TACH |
3223 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 24VDC | Square - 60mm L x 60mm H | 25.00mm | 27.5 CFM (0.770m³/min) | 0.351 in H2O (87.3 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 39.0dB(A) | 3.12 W | 5600 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |