Photo | Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Voltage-Rated | Size/Dimension | Width | AirFlow | StaticPressure | BearingType | FanType | Features | Noise | Power(Watts) | RPM | Termination | IngressProtection | OperatingTemperature | ApprovalAgency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
BFB0712H-AF0075X75X25MM 12V DC BLOWER W/SPEED |
2139 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | BFB | Active | 12VDC | Square/Rounded - 75.7mm L x 75.7mm H | 25.00mm | 13.8 CFM (0.386m³/min) | 0.773 in H2O (192.5 Pa) | Ball | Blower | Locked Rotor Protection, Speed Sensor (Tach) | 48.0dB(A) | 3.24 W | 4000 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, CSA, UL, VDE |
![]() |
BFB0712HH-AR0075X75X25MM 12V DC BLOWER W/SPEED |
2009 | QRF |
카트에 추가지금 질의 |
Box | BFB | Active | 12VDC | Square/Rounded - 75.7mm L x 75.7mm H | 25.00mm | 15.3 CFM (0.428m³/min) | 0.977 in H2O (243.4 Pa) | Ball | Blower | Locked Rotor Sensor | 51.0dB(A) | 4.08 W | 4400 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, CSA, UL, VDE | |
![]() |
DC1202512J2B-3T0FAN 12VDC 120X25MM 3WIRES |
3628 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | - | Active | 12VDC | Square - 120mm L x 120mm H | 25.00mm | 67.8 CFM (1.90m³/min) | 0.170 in H2O (42.3 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 35.0dB(A) | 2.4 W | 2100 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cURus, TUV |
![]() |
DC1202512V2B-3T0FAN 12VDC 120X25MM 3WIRES |
2113 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | - | Active | 12VDC | Square - 120mm L x 120mm H | 25.00mm | 121.0 CFM (3.39m³/min) | 0.510 in H2O (127.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 52.0dB(A) | 7.8 W | 4000 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cURus, TUV |
![]() |
OD9225-12HHBIP6812VDC 92X92X25MM IP68 |
3682 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | OD9225 | Active | 12VDC | Square - 92mm L x 92mm H | 25.00mm | 60.0 CFM (1.68m³/min) | 0.250 in H2O (62.3 Pa) | Ball | Tubeaxial | Auto Restart | 38.0dB | 3 W | 3300 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | 5 ~ 149°F (-15 ~ 65°C) | cURus, TUV |
![]() |
OD9225-12LBIP6812VDC 92X92X25MM IP68 |
2070 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | OD9225 | Active | 12VDC | Square - 92mm L x 92mm H | 25.00mm | 25.0 CFM (0.700m³/min) | 0.120 in H2O (29.9 Pa) | Ball | Tubeaxial | Auto Restart | 23.0dB | 1.4 W | 1800 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | 5 ~ 149°F (-15 ~ 65°C) | cURus, TUV |
![]() |
OD9225-12MBIP6812VDC 92X92X25MM IP68 |
3303 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | OD9225 | Active | 12VDC | Square - 92mm L x 92mm H | 25.00mm | 35.0 CFM (0.980m³/min) | 0.180 in H2O (44.8 Pa) | Ball | Tubeaxial | Auto Restart | 30.0dB | 2.1 W | 2500 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | 5 ~ 149°F (-15 ~ 65°C) | cURus, TUV |
![]() |
OD9225-24HHBIP6824VDC 92X92X25MM IP68 |
2308 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | OD9225 | Active | 24VDC | Square - 92mm L x 92mm H | 25.00mm | 60.0 CFM (1.68m³/min) | 0.250 in H2O (62.3 Pa) | Ball | Tubeaxial | Auto Restart | 38.0dB | 3.5 W | 3300 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | 5 ~ 149°F (-15 ~ 65°C) | cURus, TUV |
![]() |
OD9225-24LBIP6824VDC 92X92X25MM IP68 |
3628 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | OD9225 | Active | 24VDC | Square - 92mm L x 92mm H | 25.00mm | 25.0 CFM (0.700m³/min) | 0.120 in H2O (29.9 Pa) | Ball | Tubeaxial | Auto Restart | 23.0dB | 2.4 W | 1800 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | 5 ~ 149°F (-15 ~ 65°C) | cURus, TUV |
![]() |
OD9225-24MBIP6824VDC 92X92X25MM IP68 |
3219 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | OD9225 | Active | 24VDC | Square - 92mm L x 92mm H | 25.00mm | 35.0 CFM (0.980m³/min) | 0.180 in H2O (44.8 Pa) | Ball | Tubeaxial | Auto Restart | 30.0dB | 2.8 W | 2500 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | 5 ~ 149°F (-15 ~ 65°C) | cURus, TUV |
![]() |
CBM-979433B-235-540-22DC BLOWER, 97 X 94 X 33 MM, 24 V |
3209 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | CBM-97B-2 | Active | 24VDC | Rectangular/Rounded - 97.68mm L x 94.18mm H | 32.70mm | 23.9 CFM (0.669m³/min) | 0.900 in H2O (224.2 Pa) | Ball | Blower | Auto Restart, PWM Control, Speed Sensor (Tach) | 54.1dB(A) | 12.24 W | 3500 RPM | 4 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cURus, TUV |
![]() |
9GA0612H701DC AXIAL FAN 60X60X15MM TACH |
2387 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 15.00mm | 19.7 CFM (0.552m³/min) | 0.223 in H2O (55.5 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 34.0dB(A) | 1.2 W | 4900 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
G4020H05B2-RSR-EMFAN 40X20MM LCKD RTR IP57 05VDC |
2308 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | G4020 | Active | 5VDC | Square - 40mm L x 40mm H | 20.00mm | 11.0 CFM (0.308m³/min) | 0.200 in H2O (49.8 Pa) | Ball | Tubeaxial | Locked Rotor Sensor, Thermal Overload Protector (TOP) | 29.0dB(A) | - | 7000 RPM | 3 Wire Leads | IP57 - Dust Protected, Waterproof | - | CE, cUL, TUV, UL |
![]() |
MH4028H12B1+6-RSRDC FAN AXIAL 40X40X28MM 12VDC W/ |
2381 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | MH4028 | Active | 12VDC | Square - 40mm L x 40mm H | 28.00mm | 21.1 CFM (0.591m³/min) | 0.880 in H2O (219.2 Pa) | Ball | Tubeaxial | Auto Restart, PWM Control, Speed Sensor (Tach), Thermal Overload Protector (TOP) | 52.0dB(A) | - | 13000 RPM | 4 Wire Leads | - | - | - |
![]() |
MH4028H24B1+6-RSRDC FAN AXIAL 40X40X28MM 24VDC W/ |
2981 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | MH4028 | Active | 24VDC | Square - 40mm L x 40mm H | 28.00mm | 21.1 CFM (0.591m³/min) | 0.880 in H2O (219.2 Pa) | Ball | Tubeaxial | Auto Restart, PWM Control, Speed Sensor (Tach) | 52.0dB(A) | - | 13000 RPM | 4 Wire Leads | - | - | - |
![]() |
MA3010H05C-RSFAN AXIAL 30X10MM 5VDC WIRE |
3762 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | MA3010 | Active | 5VDC | Square - 30mm L x 30mm H | 10.00mm | 4.2 CFM (0.118m³/min) | 0.150 in H2O (37.3 Pa) | 1 Ball/1 Sleeve | Tubeaxial | Thermal Overload Protector (TOP) | 28.0dB(A) | - | 9000 RPM | 2 Wire Leads | - | - | cUL, TUV, UL |
|
9S0612F4021FAN 60X25MM 12VDC RBLS |
3869 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 25.00mm | 17.3 CFM (0.484m³/min) | 0.120 in H2O (29.9 Pa) | Ball | Tubeaxial | - | 20.0dB(A) | 960 mW | 3300 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL |
|
9S0612H4021FAN 60X25MM 12VDC RBLS |
2056 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 25.00mm | 20.5 CFM (0.574m³/min) | 0.160 in H2O (39.8 Pa) | Ball | Tubeaxial | - | 24.0dB(A) | 1.32 W | 3900 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL |
|
9S0612M4021FAN 60X25MM 12VDC RBLS |
2674 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 25.00mm | 14.1 CFM (0.395m³/min) | 0.080 in H2O (19.9 Pa) | Ball | Tubeaxial | - | 16.0dB(A) | 840 mW | 2700 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL |
![]() |
9S0824L4D011DC AXIAL FAN 80X80X25MM LOCK |
3202 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 80 | Active | 24VDC | Square - 80mm L x 80mm H | 25.00mm | 23.3 CFM (0.652m³/min) | 0.073 in H2O (18.2 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 16.0dB(A) | 960 mW | 2000 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL |