Photo | Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Voltage-Rated | Size/Dimension | Width | AirFlow | StaticPressure | BearingType | FanType | Features | Noise | Power(Watts) | RPM | Termination | IngressProtection | OperatingTemperature | ApprovalAgency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
9GA0612K1011DC AXIAL FAN 60X60X38MM TACH |
3605 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 38.00mm | 53.0 CFM (1.48m³/min) | 2.400 in H2O (597.8 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 59.0dB(A) | 11.4 W | 14800 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
OD1238-48MBXC02AFAN AXIAL 120X38.5MM 48VDC WIRE |
2652 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | OD1238 XC | Active | 48VDC | Square - 120mm L x 120mm H | 38.50mm | 175.0 CFM (4.90m³/min) | 0.510 in H2O (127.0 Pa) | Ball | Tubeaxial | Auto Restart, Locked Rotor Sensor | 57.0dB | 17 W | 3800 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | cURus, TUV |
![]() |
4712KL-04W-B10-P00FAN AXIAL 119X32MM 12VDC WIRE |
2445 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | 4712KL | Active | 12VDC | Square - 119mm L x 119mm H | 32.00mm | 56.1 CFM (1.57m³/min) | 0.088 in H2O (21.9 Pa) | Ball | Tubeaxial | - | 29.0dB | 1.92 W | 1600 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, CSA, UL, VDE |
![]() |
4712KL-04W-B20-P00FAN AXIAL 119X32MM 12VDC WIRE |
2268 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | 4712KL | Active | 12VDC | Square - 119mm L x 119mm H | 32.00mm | 82.2 CFM (2.30m³/min) | 0.168 in H2O (41.8 Pa) | Ball | Tubeaxial | - | 39.0dB | 3.84 W | 2300 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, CSA, UL, VDE |
![]() |
4712KL-04W-B30-P00FAN AXIAL 119X32MM 12VDC WIRE |
2006 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | 4712KL | Active | 12VDC | Square - 119mm L x 119mm H | 32.00mm | 99.9 CFM (2.80m³/min) | 0.241 in H2O (60.0 Pa) | Ball | Tubeaxial | - | 44.0dB | 5.76 W | 2800 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, CSA, UL, VDE |
![]() |
BFB1212EH-AF00FAN BLOWER 120X120X32MM |
3224 | QRF |
카트에 추가지금 질의 |
Bulk | BFB | Active | 12VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 54.9 CFM (1.54m³/min) | 3.485 in H2O (868.1 Pa) | Ball | Blower | Locked Rotor Protection, Speed Sensor (Tach) | 62.0dB(A) | 28.44 W | 4000 RPM | 3 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CE, CSA, UL, VDE | |
![]() |
CBM-A232B-125FAN BLOWER 120X32MM 12VDC WIRE |
2104 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Tray | CBM-120B | Active | 12VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 35.9 CFM (1.01m³/min) | 0.890 in H2O (221.7 Pa) | Ball | Blower | Auto Restart | 53.8dB(A) | 9.8 W | 2500 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cURus, TUV |
![]() |
PMD2406PMB1-A (2).GN.IP55FAN AXIAL 60X38MM 24VDC |
2846 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | PMD | Active | 24VDC | Square - 60mm L x 60mm H | 38.00mm | 56.5 CFM (1.58m³/min) | 0.920 in H2O (229.2 Pa) | Ball | Tubeaxial | Auto Restart | 56.0dB(A) | - | 8000 RPM | 2 Wire Leads | IP55 - Dust Protected, Water Resistant | 14 ~ 158°F (-10 ~ 70°C) | CE, CUR, TUV, UL |
![]() |
PMD2406PMB2-A (2).GN.IP55FAN AXIAL 60X38MM 24VDC |
3920 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | PMD | Active | 24VDC | Square - 60mm L x 60mm H | 38.00mm | 49.3 CFM (1.38m³/min) | 0.710 in H2O (176.9 Pa) | Ball | Tubeaxial | Auto Restart | 52.0dB(A) | 7.4 W | 7000 RPM | 2 Wire Leads | IP55 - Dust Protected, Water Resistant | 14 ~ 158°F (-10 ~ 70°C) | CE, CUR, TUV, UL |
![]() |
MSI1225H12B-BBRFAN IMP MTRZD 120X25MM 12VDC |
3061 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | MSI1225 | Active | 12VDC | Round - 120mm Dia | 25.80mm | 58.0 CFM (1.62m³/min) | 0.570 in H2O (142.0 Pa) | Ball | Motorized Impellers | Auto Restart | 54.0dB(A) | - | 3300 RPM | 2 Wire Leads | - | - | CE, cUL, TUV, UL |
|
AFB0648EH-TP27FAN AXIAL 60X25.4MM 48VDC WIRE |
3545 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | AFB | Active | 48VDC | Square - 60mm L x 60mm H | 25.40mm | 38.4 CFM (1.08m³/min) | 0.544 in H2O (135.5 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 46.5dB(A) | 6.72 W | 6800 RPM | 4 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, CSA, UL, VDE |
![]() |
9CRA0312K402DC AXIAL FAN 38X38X48MM |
2541 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 38 | Active | 12VDC | Square - 38mm L x 38mm H | 48.00mm | 27.2 CFM (0.762m³/min) | 2.810 in H2O (700.0 Pa) | Ball | Tubeaxial (Dual) | Counter-Rotating, Locked Rotor Protection | 64.0dB(A) | 18 W | 17600 Front, 14520 Rear | 2 Wire Leads per Fan | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |
![]() |
9CRA0412K401DC AXIAL FAN 40X40X48MM TACH |
2071 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 40 | Active | 12VDC | Square - 40mm L x 40mm H | 48.00mm | 32.5 CFM (0.910m³/min) | 2.610 in H2O (650.1 Pa) | Ball | Tubeaxial (Dual) | Counter-Rotating, Locked Rotor Protection, Speed Sensor (Tach) | 64.0dB(A) | 19.2 W | 17500 Front, 11700 Rear | 3 Wire Leads per Fan | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |
![]() |
OD9238-24HHBXCDC FAN 24V 92X92X38MM |
2733 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | OD9238 | Active | 24VDC | Square - 92mm L x 92mm H | 38.00mm | - | - | Ball | Tubeaxial | Auto Restart | - | - | - | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |
![]() |
OD9238-12HHBXCDC FAN 12V 92X92X38MM |
3452 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | OD9238 | Active | 12VDC | Square - 92mm L x 92mm H | 38.00mm | 174.0 CFM (4.87m³/min) | 1.700 in H2O (423.5 Pa) | Ball | Tubeaxial | Auto Restart, PWM Control, Speed Sensor (Tach) | 68.0dB | 42 W | 8000 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |
![]() |
OD9238-48HHBXCDC FAN 48V 92X92X38MM |
3061 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | OD9238 | Active | 48VDC | Square - 92mm L x 92mm H | 38.00mm | - | - | Ball | Tubeaxial | Auto Restart | - | - | - | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |
![]() |
9GV0612G102DC AXIAL FAN 60X60X38MM |
2950 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 38.00mm | 84.0 CFM (2.35m³/min) | 3.020 in H2O (752.3 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 66.0dB(A) | 33.6 W | 16000 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
9GV0612G1021DC AXIAL FAN 60X60X38MM |
3568 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 12VDC | Square - 60mm L x 60mm H | 38.00mm | 84.0 CFM (2.35m³/min) | 3.020 in H2O (752.3 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 66.0dB(A) | 33.6 W | 16000 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
9GV0624G102DC AXIAL FAN 60X60X38MM |
2987 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 24VDC | Square - 60mm L x 60mm H | 38.00mm | 84.0 CFM (2.35m³/min) | 3.020 in H2O (752.3 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 66.0dB(A) | 33.6 W | 16000 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |
![]() |
9GV0624G1021DC AXIAL FAN 60X60X38MM |
2233 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 24VDC | Square - 60mm L x 60mm H | 38.00mm | 84.0 CFM (2.35m³/min) | 3.020 in H2O (752.3 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 66.0dB(A) | 33.6 W | 16000 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL |