Photo | Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Voltage-Rated | Size/Dimension | Width | AirFlow | StaticPressure | BearingType | FanType | Features | Noise | Power(Watts) | RPM | Termination | IngressProtection | OperatingTemperature | ApprovalAgency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
OD9238-48MB-VXC5FAN AXIAL 92.5X38MM 48VDC WIRE |
2041 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | OD9238 VA | Active | 48VDC | Square - 92.5mm L x 92.5mm H | 38.00mm | 118.0 CFM (3.30m³/min) | 0.590 in H2O (147.0 Pa) | Ball | Tubeaxial | Auto Restart, PWM Control | 55.0dB | 12 W | 4800 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | cURus, TUV |
![]() |
ODB1232-12HBFAN BLOWER 120X32MM 12VDC WIRE |
2031 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | ODB1232 | Active | 12VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 33.0 CFM (0.924m³/min) | 0.920 in H2O (229.2 Pa) | Ball | Blower | - | 55.0dB | - | 2600 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus |
![]() |
ODB1232-12MBFAN BLOWER 120X32MM 12VDC WIRE |
2035 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | ODB1232 | Active | 12VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 28.0 CFM (0.784m³/min) | 0.830 in H2O (206.7 Pa) | Ball | Blower | - | 49.0dB | - | 2300 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus |
![]() |
ODB1232-12LBFAN BLOWER 120X32MM 12VDC WIRE |
2079 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | ODB1232 | Active | 12VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 25.0 CFM (0.700m³/min) | 0.660 in H2O (164.4 Pa) | Ball | Blower | - | 48.0dB | - | 2100 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus |
![]() |
ODB1232-24HBFAN BLOWER 120X32MM 24VDC WIRE |
2290 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | ODB1232 | Active | 24VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 33.0 CFM (0.924m³/min) | 0.920 in H2O (229.2 Pa) | Ball | Blower | - | 55.0dB | - | 2600 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus |
![]() |
ODB1232-24MBFAN BLOWER 120X32MM 24VDC WIRE |
3213 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | ODB1232 | Active | 24VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 28.0 CFM (0.784m³/min) | 0.830 in H2O (206.7 Pa) | Ball | Blower | - | 49.0dB | - | 2300 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus |
![]() |
ODB1232-24LBFAN BLOWER 120X32MM 24VDC WIRE |
3197 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | ODB1232 | Active | 24VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 25.0 CFM (0.700m³/min) | 0.660 in H2O (164.4 Pa) | Ball | Blower | - | 48.0dB | - | 2100 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus |
![]() |
ODB1232-48HBFAN BLOWER 120X32MM 48VDC WIRE |
2346 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | ODB1232 | Active | 48VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 33.0 CFM (0.924m³/min) | 0.920 in H2O (229.2 Pa) | Ball | Blower | - | 55.0dB | - | 2600 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |
![]() |
ODB1232-48MBFAN BLOWER 120X32MM 48VDC WIRE |
2138 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | ODB1232 | Active | 48VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 28.0 CFM (0.784m³/min) | 0.830 in H2O (206.7 Pa) | Ball | Blower | - | 49.0dB | - | 2300 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |
![]() |
ODB1232-48LBFAN BLOWER 120X32MM 48VDC WIRE |
3651 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | ODB1232 | Active | 48VDC | Square/Rounded - 120mm L x 120mm H | 32.00mm | 25.0 CFM (0.700m³/min) | 0.660 in H2O (164.4 Pa) | Ball | Blower | - | 48.0dB | - | 2100 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |
![]() |
F1238E48B1-FSR-TTL-L10FAN AXIAL 119X38MM 48VDC WIRE |
3842 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | F1238-S | Active | 48VDC | Square - 119mm L x 119mm H | 38.00mm | 126.0 CFM (3.53m³/min) | 0.280 in H2O (69.7 Pa) | Ball | Tubeaxial | Auto Restart, Locked Rotor Protection, Speed Sensor (Tach) | 43.0dB(A) | - | 2800 RPM | 3 Wire Leads | - | - | CE, cUL, TUV, UL |
![]() |
F1238H24B2-FSR-L16FAN AXIAL 119X38MM 24VDC WIRE |
2258 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | F1238-H | Active | 24VDC | Square - 119mm L x 119mm H | 38.00mm | 115.0 CFM (3.22m³/min) | 0.250 in H2O (62.3 Pa) | Ball | Tubeaxial | Auto Restart, Locked Rotor Sensor | 41.0dB(A) | - | 2500 RPM | 3 Wire Leads | - | - | CE, cUL, TUV, UL |
![]() |
109R0648J4D01DC AXIAL FAN 60X60X25MM LOCK |
3763 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace 60 | Active | 48VDC | Square - 60mm L x 60mm H | 25.00mm | 37.1 CFM (1.04m³/min) | 0.622 in H2O (155.0 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 44.0dB(A) | 5.76 W | 7600 RPM | 3 Wire Leads | - | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL |
![]() |
UF3F3-500TCFAN AXIAL 15X3 3VDC VAPO |
2041 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Tray | MagLev® UF, Mighty Mini | Active | 3VDC | Square - 15mm L x 15mm H | 3.00mm | 0.309 CFM (0.009m³/min) | 0.082 in H2O (20.4 Pa) | Vapo-Bearing™ | Tubeaxial | Auto Restart, Speed Sensor (Tach) | 30.0dB(A) | 100 mW | 14500 RPM | 3 Wire Leads | IP55 - Dust Protected, Water Resistant | 14 ~ 158°F (-10 ~ 70°C) | CE |
![]() |
UB3C3-500TCFAN BLOWER 12X3 3VDC VAPO |
2916 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Tray | MagLev® UB, Mighty Mini | Active | 3VDC | Square - 12mm L x 12mm H | 3.00mm | 0.094 CFM (0.003m³/min) | 0.092 in H2O (23.0 Pa) | Vapo-Bearing™ | Blower | Auto Restart, Speed Sensor (Tach) | 26.0dB(A) | 100 mW | 15500 RPM | 3 Wire Leads | IP55 - Dust Protected, Water Resistant | 14 ~ 158°F (-10 ~ 70°C) | CE |
![]() |
UB3F3-500TCFAN BLOWER 15X3 3VDC VAPO |
2459 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Bulk | MagLev® UB, Mighty Mini | Active | 3VDC | Square - 15mm L x 15mm H | 3.00mm | 0.170 CFM (0.005m³/min) | 0.136 in H2O (33.9 Pa) | Vapo-Bearing™ | Blower | Auto Restart, Speed Sensor (Tach) | 30.0dB(A) | 100 mW | 14000 RPM | 3 Wire Leads | IP55 - Dust Protected, Water Resistant | 14 ~ 158°F (-10 ~ 70°C) | CE |
![]() |
PMD4807PTB1-A.(2).U.GNFAN AXIAL 70X25MM 48VDC WIRE |
3546 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | PMD | Active | 48VDC | Square - 70mm L x 70mm H | 25.00mm | 49.0 CFM (1.37m³/min) | 0.360 in H2O (89.7 Pa) | Ball | Tubeaxial | - | 45.0dB(A) | 5.8 W | 5100 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, CUR, TUV, UL |
![]() |
9BD24FA6-1BLOWER 76X20MM 24VDC |
2351 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace B76 | Active | 24VDC | Rectangular/Rounded - 76mm L x 69.7mm H | 20.00mm | 8.8 CFM (0.246m³/min) | 0.800 in H2O (199.3 Pa) | Ball | Blower | Locked Rotor Protection | 39.0dB(A) | 2.4 W | 3900 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |
![]() |
9BD12FA6-1DC BLOWER 76X20MM |
3118 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace B76 | Active | 12VDC | Rectangular/Rounded - 76mm L x 69.7mm H | 20.00mm | 8.8 CFM (0.246m³/min) | 0.800 in H2O (199.3 Pa) | Ball | Blower | Locked Rotor Protection | 39.0dB(A) | 2.16 W | 3900 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |
![]() |
9BD12HA6-1DC BLOWER 76X20MM |
2536 | QRF |
카트에 추가지금 질의 |
![]() Datasheet |
Box | San Ace B76 | Active | 12VDC | Rectangular/Rounded - 76mm L x 69.7mm H | 20.00mm | 9.5 CFM (0.266m³/min) | 0.920 in H2O (229.2 Pa) | Ball | Blower | Locked Rotor Protection | 41.0dB(A) | 2.52 W | 4200 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV |