Photo | Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | HoldingTemperature | RatedFunctioningTemperature | ResetTemperature | VoltageRating-AC | VoltageRating-DC | CurrentRating(Amps) | ApprovalAgency | MaximumTemperatureLimit |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MHP-TAM15-9-77NMHP-TAM15-9-77N |
995 | 1.64 |
Add To CartInquiry Now |
Bulk | MHP-TAM | Active | Breaker | - | 77°C (171°F) | 40°C (104°F) | - | 9 | 12 A | cUL, UL | - | ||
MHP-TAM15-9-72NMHP-TAM15-9-72N |
995 | 1.64 |
Add To CartInquiry Now |
Bulk | MHP-TAM | Active | Breaker | - | 72°C (162°F) | 40°C (104°F) | - | 9 | 12 A | cUL, UL | - | ||
MHP-TAM15-9-85NMHP-TAM15-9-85N |
995 | 1.72 |
Add To CartInquiry Now |
Bulk | MHP-TAM | Active | Breaker | - | 85°C (185°F) | 40°C (104°F) | - | 9 | 12 A | cUL, UL | - | ||
MHP-TAM15-9-82NMHP-TAM15-9-82N |
995 | 1.72 |
Add To CartInquiry Now |
Bulk | MHP-TAM | Active | Breaker | - | 82°C (180°F) | 40°C (104°F) | - | 9 | 12 A | cUL, UL | - | ||
MHP-TAM15-9-72THERMOSTAT 72DEG C SPST-NC STRAP |
251 | 1.64 |
Add To CartInquiry Now |
Datasheet |
Bag | MHP-TAM | Active | Breaker | - | 72°C (162°F) | 40°C (104°F) | - | 9 | 12 A | cUL, UL | - | |
MHP-TAM15-9-90THERMOSTAT 90DEG C SPST-NC STRAP |
458 | 1.72 |
Add To CartInquiry Now |
Datasheet |
Bag | MHP-TAM | Active | Breaker | - | 90°C (194°F) | 40°C (104°F) | - | 9 | 12 A | cUL, UL | - | |
MHP-TAC6-12-72THERMOSTAT 72DEG C SPST-NC STRAP |
832 | 1.73 |
Add To CartInquiry Now |
Datasheet |
Bulk | MHP-TAC | Not For New Designs | Breaker | - | 72°C (162°F) | 40°C (104°F) | - | 12 | 25 A | - | - | |
MHP-TAC6-12-82THERMOSTAT 82DEG C SPST-NC STRAP |
2514 | 1.79 |
Add To CartInquiry Now |
Datasheet |
Bulk | MHP-TAC | Not For New Designs | Breaker | - | 82°C (180°F) | 40°C (104°F) | - | 12 | 25 A | - | - | |
MHP-TAC15-12-77THERMOSTAT 77DEG C SPST-NC STRAP |
2345 | 1.81 |
Add To CartInquiry Now |
Datasheet |
Bulk | MHP-TAC | Not For New Designs | Breaker | - | 77°C (171°F) | 40°C (104°F) | - | 12 | 25 A | - | - | |
MHP-TAT18-9-85NTHERMOSTAT 85DEG C SPST-NC STRAP |
987 | 1.81 |
Add To CartInquiry Now |
Datasheet |
Bag | MHP-TAT18 | Active | Breaker | - | 85°C (185°F) | 40°C (104°F) | - | 28 | 30 A | cURus | - | |
MHP-TAT18-9-77NTHERMOSTAT 77DEG C SPST-NC STRAP |
985 | 1.81 |
Add To CartInquiry Now |
Datasheet |
Bag | MHP-TAT18 | Active | Breaker | - | 77°C (171°F) | 40°C (104°F) | - | 28 | 30 A | cURus | - | |
MHP-TAC15-12-72THERMOSTAT 72DEG C SPST-NC STRAP |
763 | 1.87 |
Add To CartInquiry Now |
Datasheet |
Bulk | MHP-TAC | Not For New Designs | Breaker | - | 72°C (162°F) | 40°C (104°F) | - | 12 | 25 A | - | - | |
MHP-TAT18-9-82NTHERMOSTAT 82DEG C SPST-NC STRAP |
994 | 1.89 |
Add To CartInquiry Now |
Datasheet |
Bag | MHP-TAT18 | Active | Breaker | - | 82°C (180°F) | 40°C (104°F) | - | 28 | 30 A | cURus | - | |
MHP-TAT18-9-72NTHERMOSTAT 72DEG C SPST-NC STRAP |
981 | 1.89 |
Add To CartInquiry Now |
Datasheet |
Bag | MHP-TAT18 | Active | Breaker | - | 72°C (162°F) | 40°C (104°F) | - | 28 | 30 A | cURus | - | |
USW-116TTHERMAL CUTOFF (THERMAL FUSE) 25 |
3016 | 0.99 |
Add To CartInquiry Now |
Datasheet |
Bag | SW-1 | Active | Fuse | 127°C (261°F) | 152°C (306°F) | - | 250 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - | |
USW-122TTHERMAL CUTOFF (THERMAL FUSE) 25 |
965 | 0.99 |
Add To CartInquiry Now |
Datasheet |
Bag | SW-1 | Active | Fuse | 162°C (324°F) | 192°C (378°F) | - | 250 | - | 10 A | PSE | - | |
USW-139TTHERMAL CUTOFF (THERMAL FUSE) 25 |
945 | 0.99 |
Add To CartInquiry Now |
Datasheet |
Bag | SW-1 | Active | Fuse | 178°C (352°F) | 216°C (421°F) | - | 250 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - | |
USW-138TTHERMAL CUTOFF (THERMAL FUSE) 25 |
900 | 0.99 |
Add To CartInquiry Now |
Datasheet |
Bag | SW-1 | Active | Fuse | 119°C (246°F) | 144°C (291°F) | - | 250 | - | 10 A | PSE | - | |
USW-102TTHERMAL CUTOFF (THERMAL FUSE) 25 |
775 | 0.99 |
Add To CartInquiry Now |
Datasheet |
Bag | SW-1 | Active | Fuse | 47°C (117°F) | 72°C (162°F) | - | 250 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - | |
USW-129TTHERMAL CUTOFF (THERMAL FUSE) 25 |
670 | 0.99 |
Add To CartInquiry Now |
Datasheet |
Bag | SW-1 | Active | Fuse | 103°C (217°F) | 128°C (262°F) | - | 250 | - | 10 A | CCC, cUL, PSE, TUV, VDE, UL | - |
Tel