Photo | Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | Type | Function | ActuatorType | OperatingPressure | OrificeDiameter | FluidType | ConnectionMethod | ForUseWith/RelatedProducts | MountingType |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
81921701POSITION DETECT 3/2 NC CHAS MNT |
361 | 47.28 |
Add To CartInquiry Now |
Datasheet |
Box | Miniature | Active | Position Detector | 3/2 Normally Closed | Lever, Roller | 1 ~ 116PSI (0.1 ~ 8 bar) | 0.106 (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32 (4.00mm) Dia | - | Chassis Mount | |
81921702POSITION DETECT 3/2 NC CHAS MNT |
136 | 74.39 |
Add To CartInquiry Now |
Datasheet |
Box | Miniature | Active | Position Detector | 3/2 Normally Closed | Lever, Roller | 1 ~ 116PSI (0.1 ~ 8 bar) | 0.106 (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32 (4.00mm) Dia | - | Chassis Mount | |
81506940FREQ GENERATOR SUB-BASE MOUNT |
3373 | 189.83 |
Add To CartInquiry Now |
Datasheet |
Box | - | Active | Frequency Generator | - | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106 (2.70mm) | Air, Inert Gas | - | - | Sub-Base Mount | |
ROB-10456SOLENOID VALVE ONEWAY FREE HANG |
191 | 8.95 |
Add To CartInquiry Now |
Datasheet |
Bulk | - | Active | Solenoid Valve | 2/2 Normally Closed | - | 2.9 ~ 116.03 PSI (0.2 ~ 8 bar) | - | Liquid | Threaded 3/4 NPT | - | Free Hanging (In-Line) | |
81540001LOGIC OR ELEMENT FREE HANGING |
151 | 28.59 |
Add To CartInquiry Now |
Datasheet |
Box | - | Active | Logic Element | LOGIC OR | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106 (2.70mm) | Air, Inert Gas | Push-In Connection for Tubing 5/32 (4.00mm) Dia | - | Free Hanging (In-Line) | |
81504025SENSOR LOGIC NOT SUB-BASE MOUNT |
120 | 34.26 |
Add To CartInquiry Now |
Datasheet |
Box | - | Active | Sensor, Pressure Decay | LOGIC NOT | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106 (2.70mm) | Air, Inert Gas | - | - | Sub-Base Mount | |
81513509SWITCH PRESSURE OPERATED DIN RL |
2524 | 84.94 |
Add To CartInquiry Now |
Datasheet |
Bulk | - | Active | Pressure Switch | Pressure Operated | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | Push-In Connection for Tubing 5/32 (4.00mm) Dia | - | DIN Rail | |
81507540IMPULSE GENERATOR SUB-BASE MOUNT |
2757 | 146.92 |
Add To CartInquiry Now |
Datasheet |
Box | - | Active | Impulse Generator, Fixed | - | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106 (2.70mm) | Air, Inert Gas | - | - | Sub-Base Mount | |
81580101CONTROL RELAY ONEWAY SUBBASE MNT |
3364 | 235.70 |
Add To CartInquiry Now |
Datasheet |
Box | - | Active | Control Relay | One-Way | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.098 (2.50mm) | Air, Inert Gas | - | - | Sub-Base Mount | |
997PLASTIC WATER SOLENOID VALVE - 1 |
434 | 6.95 |
Add To CartInquiry Now |
Datasheet |
Bulk | - | Active | Solenoid Valve | 2/2 Normally Closed | - | 3 ~ 116 PSI (0.21 ~ 8 bar) | - | Liquid | Threaded 1/2 NPS | - | Free Hanging (In-Line) | |
111990004SOLENOID VALVE ONE-WAY PANEL MNT |
125 | 8.50 |
Add To CartInquiry Now |
Datasheet |
Bulk | - | Active | Solenoid Valve | 2/2 Normally Closed | - | 2.9 ~ 116.03 PSI (0.2 ~ 8 bar) | - | Liquid | Threaded 1/2 BSP | - | Panel Mount | |
996SOLENOID VALVE ONEWAY FREE HANG |
163 | 24.95 |
Add To CartInquiry Now |
Datasheet |
Bulk | - | Active | Solenoid Valve | 2/2 Normally Closed | - | 0 ~ 140PSI (0 ~ 10 bar) | - | Liquid | Threaded 1/2 NPS | - | Free Hanging (In-Line) | |
81513200CONTROL VALVE 4/2 SUBBASE MNT |
173 | 43.88 |
Add To CartInquiry Now |
Datasheet |
Box | - | Active | Control Valve, Momentary | 4/2 | - | 44 ~ 116 PSI (3 ~ 8 bar) | 0.118 (3.00mm) | Air, Inert Gas | - | - | Sub-Base Mount | |
81550001SEQUENCER SUB-BASE MOUNT |
2684 | 132.17 |
Add To CartInquiry Now |
Datasheet |
Box | - | Active | Sequencer | - | - | 30 ~ 116 PSI (2 ~ 8 bar) | 0.106 (2.70mm) | Air, Inert Gas | - | - | Sub-Base Mount | |
BM-91-310-HNR-1313/2-WAY NC, ELECTRICALLY OPERATE |
3612 | 68.85 |
Add To CartInquiry Now |
Datasheet |
Box | BM | Active | Solenoid Valve | 3/2 Normally Closed | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | |
BM-91-310-HNR-1623/2-WAY NC, ELECTRICALLY OPERATE |
2719 | 68.85 |
Add To CartInquiry Now |
Datasheet |
Box | BM | Active | Solenoid Valve | 3/2 Normally Closed | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | |
BM-91-310-HNR-1613/2-WAY NC, ELECTRICALLY OPERATE |
2757 | 68.85 |
Add To CartInquiry Now |
Datasheet |
Box | BM | Active | Solenoid Valve | 3/2 Normally Closed | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | |
BM-91-511-HNR-1625/2 WAY, ELECTRICALLY OPERATED P |
3629 | 68.94 |
Add To CartInquiry Now |
Datasheet |
Box | BM | Active | Solenoid Valve | 5/2 | - | 44 ~ 116 PSI (3 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | |
BM-92-310-HNR-1623/2-WAY NC, ELECTRICALLY OPERATE |
3876 | 70.80 |
Add To CartInquiry Now |
Datasheet |
Box | BM | Active | Solenoid Valve | 3/2 Normally Closed | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount | |
BM-92-310-HNR-1313/2-WAY NC, ELECTRICALLY OPERATE |
2491 | 70.80 |
Add To CartInquiry Now |
Datasheet |
Box | BM | Active | Solenoid Valve | 3/2 Normally Closed | - | 30 ~ 116 PSI (2 ~ 8 bar) | - | Air, Inert Gas | - | - | Chassis Mount |
Tel